• Home
  • ASTM / AAMA Water Testing
    • storefront / curtain wall testing
    • water intrusion testing
    • forensic water intrusion testing
    • masonry wall drainage testing
    • wall penetration testing
  • Infrared Thermography
    • exterior cladding surveys
    • construction defect investigations
    • building envelope survey
    • cell fill (cmu) evaluations
    • eifs inspections
    • commercial roof surveys
    • water infiltration detection & documentation
    • energy audits
    • infrared electrical inspections
  • About BDG
    • mission statement
    • meet our team
    • our proven process
  • Resources
    • downloads
    • faqs
    • helpful links
  • Contact Us

ASTM E1105

ASTM E1105 - Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference.
ASTM
Significance and Use

This test method is a standard procedure for determining the resistance to water penetration under uniform or cyclic static air pressure differences of installed exterior windows, skylights, curtain walls, and doors. The air-pressure differences acting across a building envelope vary greatly. These factors should be considered fully prior to specifying the test pressure difference to be used.

 1. Scope

1.1 This test method covers the determination of the resistance of installed exterior windows, curtain walls, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face.

1.2 This test method is applicable to any curtain-wall area or to windows, skylights, or doors alone. It is intended primarily for determining the resistance to water penetration through such assemblies for compliance with specified performance criteria, but it may also be used to determine the resistance to penetration through the joints between the assemblies and the adjacent construction. Other procedures may be appropriate to identify sources of leakage.

1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues.

1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement.

1.5 The values stated in SI units are to be regarded as the standard. The inch-pound equivalents of SI units may be approximate.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

An in-depth evaluation of the building envelope enables the architect/engineer to develop accurate specifications for contractor bidding that are also used during construction. The quality of the initial field evaluation directly affects the quality and performance of repairs, as outlined in the specification documents. A thorough investigation also promotes an efficient design specification, thereby reducing the possibility of increased costs via change orders due to unforeseen conditions.

The time and expense of performing an initial, well-focused evaluation will save the building owner money in the long run and result in repairs that extend the service life of the building.

Contact our office today for more information about all of our forensic water testing services.

ASTM / AAMA Water Testing

  • Storefront / Curtain Wall Testing
  • Water Intrusion Testing
  • Forensic Water Intrusion Testing
  • Masonry Wall Drainage Testing
  • Wall Penetration Testing

ASTM & AAMA Testing Services

  • ASTM E 331
  • ASTM E 547
  • ASTM E 783
  • ASTM E 1105
  • ASTM C 1601
  • ASTM C 1715
  • AAMA 501.2
  • AAMA 502
  • AAMA 503

Diagnostic Water Intrusion Testing

  • ASTM E 2128
  • AAMA 511
© 2013 Building Diagnostics Group, INC. (BDG)
CONTACT US | TERMS OF USE | PRIVACY POLICY | SITE MAP
  • ASTM / AAMA SERVICES

  • » Storefront / Curtain Wall Testing
  • » Water Intrusion Testing
  • » Forensic Water Intrusion Testing
  • » Masonry Wall Drainage Testing
  • » Wall Penetration Testing
  • INFRARED THERMOGRAPHY

  • » Exterior Cladding Surveys
  • » Building Envelope Survey
  • » Cell Fill Evaluations (CMU)
  • » Commercial Roof Surveys
  • » Infrared Electrical Inspections
ATLANTA
(404) 949-9939
NATIONWIDE
(888) 317-4568